Ignition protection type | EEx dm IIC T5

3/2-way valves


MH 310 _ _1 Ex dm | MOH 310 _ _1 Ex dm

MH 310 _ _1 Ex dm | MOH 310 _ _1 Ex dm

Explosionsgeschützte Magnetventile | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

MH 310 _ _1 Ex dm | MOH 310 _ _1 Ex dm
Type number Port size Air flow Operating pressure Funktion Power consumption Datasheet
MH 310 501 Ex dm G 1/8" 650 l/min 2...10 bar monostabil | NC 3 W / 5 VA Datasheet »
MOH 310 501 Ex dm G 1/8" 650 l/min 2...10 bar monostabil | NO 3 W / 5 VA Datasheet »
MH 310 701 Ex dm G 1/4" 1250 l/min 2...10 bar monostabil | NC 3 W / 5 VA Datasheet »
MOH 310 701 Ex dm G 1/4" 1250 l/min 2...10 bar monostabil | NO 3 W / 5 VA Datasheet »
MH 310 801 Ex dm G 1/4" 1450 l/min 1,5...10 bar monostabil | NC 3 W / 5 VA Datasheet »
MOH 310 801 Ex dm G 1/4" 1450 l/min 1,5...10 bar monostabil | NO 3 W / 5 VA Datasheet »
MH 310 101 Ex dm G 3/8" 2250 l/min 1,5...10 bar monostabil | NC 3 W / 5 VA Datasheet »
MOH 310 101 Ex dm G 3/8" 2250 l/min 1,5...10 bar monostabil | NO 3 W / 5 VA Datasheet »
MH 310 121 Ex dm G 1/2" 3000 l/min 1...10 bar monostabil | NC 3 W / 5 VA Datasheet »
MOH 310 121 Ex dm G 1/2" 3000 l/min 1...10 bar monostabil | NO 3 W / 5 VA Datasheet »

« Back